RZ-D-YEDFA-1550-33-FC/APC
Working Environmental indicators
Number | Parameters | Min | Typical | Max | Unit | Remarks |
1 | Operating temperature | -5 | 50 | °C | ||
2 | Storage temperature | -40 | 85 | °C | ||
3 | Transportation temperature | -40 | 85 | °C | ||
4 | Operating humidity | 5 | 95 | % | Telcordia GR-63 |
RZ-D-YEDFA-1550-33-FC/APC
Working Environmental indicators
Number | Parameters | Min | Typical | Max | Unit | Remarks |
1 | Operating temperature | -5 | 50 | °C | ||
2 | Storage temperature | -40 | 85 | °C | ||
3 | Transportation temperature | -40 | 85 | °C | ||
4 | Operating humidity | 5 | 95 | % | Telcordia GR-63 |
Parameters | Min | Typical | Max | Unit | Remarks |
Wavelength | 1540 | 1550.12 | 1570 | nm | |
Return Loss | 45 | - | - | dB | |
Fiber Type | SMF-28e | IN & OUT | |||
Connectors Type | FC/APC | IN & OUT | |||
Operation mode | APC(default) ACC | ||||
Output power stability | ±0.1 | dB | |||
Power reporting fineness | ±0.5 | dB | |||
Optical isolation | 30 | dB | IN & OUT | ||
PM dispersion | 0.5 | ps | |||
Input average power | -10 | - | 10 | dBm | |
Gain Range | - | - | 37 | dB | |
Output average power | 23 | 33 | 34 | dBm | |
Noise figure | - | 5.5 | 6 | dB | @Output=33dBm |
Input optical power alarm | -13 | - | 9 | dBm | Range:-13~9dBm,Upward hysteresis 1dB, Prompt no power @ <-16dBm |
Output optical power alarm | 20 | - | 33 | dBm | Range:20~33dBm,Upward hysteresis 1dB, Prompt no power @ <17dBm |
Turn off the pump gate limit | -13 | - | 9 | dBm | Range:-13~9dBm,Upward hysteresis 1dB |
ACC mode current control accuracy | ±5% |
Parameters | Min | Typical | Max | Unit | Remarks |
Wavelength | 1540 | 1550.12 | 1570 | nm | |
Return Loss | 45 | - | - | dB | |
Fiber Type | SMF-28e | IN & OUT | |||
Connectors Type | FC/APC | IN & OUT | |||
Operation mode | APC(default) ACC | ||||
Output power stability | ±0.1 | dB | |||
Power reporting fineness | ±0.5 | dB | |||
Optical isolation | 30 | dB | IN & OUT | ||
PM dispersion | 0.5 | ps | |||
Input average power | -10 | - | 10 | dBm | |
Gain Range | - | - | 37 | dB | |
Output average power | 23 | 33 | 34 | dBm | |
Noise figure | - | 5.5 | 6 | dB | @Output=33dBm |
Input optical power alarm | -13 | - | 9 | dBm | Range:-13~9dBm,Upward hysteresis 1dB, Prompt no power @ <-16dBm |
Output optical power alarm | 20 | - | 33 | dBm | Range:20~33dBm,Upward hysteresis 1dB, Prompt no power @ <17dBm |
Turn off the pump gate limit | -13 | - | 9 | dBm | Range:-13~9dBm,Upward hysteresis 1dB |
ACC mode current control accuracy | ±5% |